Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 2, 2019, 11:18 AM
  • 02 1098_02 1097_522019_051430.mp4

Date
05/02/2019
W/O
0768647
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00300
PipeID
P03671
Time
4:18 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1194
Sewer Name
02 RANDOLPH STREET TRUNK
City
BELL GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Maintenance Related
Project
20190502MDM_RANDOLPH_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 1098
Downstream MH
02 1097
Dir. of Survey
Downstream
Length Surveyed
345.8 ft.
Total Length
345.8 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 1098 to 02 1097
MH: 02 1098MH: 02 1097downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:15AM13.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open13.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES33 ft. MGO - General Observation - 15" VCP- LONG FRACTURES171.4 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SLIGHT LONG FRACTURE OFFSET THROUGHOUT REACH175.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SLIGHT LONG FRACTURE OFFSET THROUGHOUT REACH240.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active309.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active345.4 ft. MGO - General Observation - NO POWER POLES OR HEAVY CRACKING OBSERVED345.8 ft. AMH - Downstream Manhole, Survey Ends - 5:40AM

Observation photos (3)

  • General Observation - 15" VCP- LONG FRACTURES

    33 ft. - General Observation - 15" VCP- LONG FRACTURES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SLIGHT LONG FRACTURE OFFSET THROUGHOUT REACH

    171.4 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SLIGHT LONG FRACTURE OFFSET THROUGHOUT REACH

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SLIGHT LONG FRACTURE OFFSET THROUGHOUT REACH

    175.1 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SLIGHT LONG FRACTURE OFFSET THROUGHOUT REACH

Observations (12)

DistanceCodeObservation
13.4TFOpen
171.4FLSLIGHT LONG FRACTURE OFFSET THROUGHOUT REACH
33MGO15" VCP- LONG FRACTURES
345.8AMH5:40AM
240.2TFActive
0MWL
13.5DAGS
345.4MGONO POWER POLES OR HEAVY CRACKING OBSERVED
175.1FLSLIGHT LONG FRACTURE OFFSET THROUGHOUT REACH
0MWM
309.7TFActive
0AMH5:15AM

Properties (5)

additional_info
POWER POLE & HEAVY CRACKING INSPECTION
customer
LACSD
datetime
2019-05-02T04:18:39-07:00
documentation
MARTIN,REVELES,OLIVER 111,RUVALCABA
is_lateral_inspection
false