Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 24, 2019, 05:52 PM
  • A 0328_A 0327_4242019_105519.mp4

Date
04/24/2019
W/O
0767441
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00325
PipeID
P08238
Time
10:52 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7969
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
22
Purpose
Capital Improvement Program Assesment
Project
20190424DF_JOA_1A_SAN_JOSE_CREEK_WRP_INT
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Upstream MH
A 0327
Downstream MH
A 0328
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
5
O&M Quick
5141
O&M Rating
9
Overall Index
4
Overall Quick
Overall Rating
12
Pipe schematic from manhole A 0327 to A 0328
MH: A 0327MH: A 0328upstream0 ft. MSA - Survey Abandoned - HIGH WATER0.1 ft. LFW - Lining Failure Wrinkled, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. MWM - Water Mark, 100 %of cross sectional area2.1 ft. LU - Alignment Up, 45 %2.1 ft. MGP - General Photograph - AIRLINE2.1 ft. MWL - Water Level, 100 %of cross sectional area2.1 ft. AMH - Downstream Manhole, Survey Begins - 10:52 AM2.1 ft. MGO - General Observation - Grease Throughout The Reach (5%)

Observation photos (2)

  • General Photograph - AIRLINE

    0 ft. - General Photograph - AIRLINE

  • Lining Failure Wrinkled, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Lining Failure Wrinkled, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0MWM
0LU
2.1MSAHIGH WATER
0MGPAIRLINE
0MWL
2LFW
0AMH10:52 AM
0MGOGrease Throughout The Reach (5%)

Properties (6)

additional_info
VIEW OF THE UPLEG FROM THE D/S SIPHON
custom_field_two
5
customer
LACSD
datetime
2019-04-24T10:52:00-07:00
documentation
FRANKLIN, CASTILLO, IGNACIO
is_lateral_inspection
false