- Date
- 02/27/2019
- W/O
- 0757008
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00793
- PipeID
- P16553
- Time
- 10:50 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Jetting
- Media Label
- G7927
- Sewer Name
- 22 CAMERON TRUNK, SECTS 1,2,&3
- City
- WEST COVINA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 31
- Purpose
- Maintenance Related
- Project
- 20190227DF_CAMERON_TRUNK_SECTS_1_2_3
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 22 1388
- Downstream MH
- 22 0268
- Dir. of Survey
- Downstream
- Length Surveyed
- 45.5 ft.
- Total Length
- 45.5 ft.
- Structural Index
- 3
- Structural Quick
- 3321
- Structural Rating
- 11
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 11
Pipe schematic from manhole 22 1388 to 22 0268 Observation photos (7)

2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

8 ft. - General Photograph

34.1 ft. - General Photograph

38.9 ft. - General Photograph