Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 25, 2019, 04:51 PM
  • J 0386_J 0413_2252019_093848.mp4

Date
02/25/2019
W/O
0756102
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00057
PipeID
P22123
Time
8:51 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1127
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
SAN PEDRO
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
48
Purpose
Capital Improvement Program Assesment
Project
20190225SHO_JOINT_OUTFALL_J_UNIT_1E
Shape
Circular
Upstream MH
J 0386
Downstream MH
J 0413
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
4
Structural Quick
5232
Structural Rating
16
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
16
Pipe schematic from manhole J 0386 to J 0413
MH: J 0386MH: J 0413downstream0 ft. MWL - Water Level, 5 %of cross sectional area - STAGNANT WATER0 ft. AMH - Upstream Manhole, Survey Begins - WEST SIDE OF VAULT2 ft. SAV - Surface Aggregate Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - SOUTH WALL OF THE WEST SIDE OF THE VAULT2 ft. AMH - Downstream Manhole, Survey Ends - FINISHED WITH WEST SIDE OF VAULT2 ft. SRV - Surface Reinforcement Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - ROOF OF THE WEST SIDE OF VAULT2 ft. SRV - Surface Reinforcement Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - REBAR IS VISIBLE AT THE VERY TOP PORTION OF WEST WALL, ALSO HAS AGGREGATE THROUGHOUT2 ft. SAV - Surface Aggregate Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - NORTH WALL OF THE WEST SIDE OF VAULT

Observation photos (4)

  • Surface Aggregate Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - SOUTH WALL OF THE WEST SIDE OF THE VAULT

    2 ft. - Surface Aggregate Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - SOUTH WALL OF THE WEST SIDE OF THE VAULT

  • Surface Reinforcement Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - ROOF OF THE WEST SIDE OF VAULT

    2 ft. - Surface Reinforcement Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - ROOF OF THE WEST SIDE OF VAULT

  • Surface Reinforcement Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - REBAR IS VISIBLE AT THE VERY TOP PORTION OF WEST WALL, ALSO HAS AGGREGATE THROUGHOUT

    2 ft. - Surface Reinforcement Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - REBAR IS VISIBLE AT THE VERY TOP PORTION OF WEST WALL, ALSO HAS AGGREGATE THROUGHOUT

  • Surface Aggregate Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - NORTH WALL OF THE WEST SIDE OF VAULT

    2 ft. - Surface Aggregate Visible, from 12 to 12 o'clock, within 8 inches of joint: NO - NORTH WALL OF THE WEST SIDE OF VAULT

Observations (7)

DistanceCodeObservation
0MWLSTAGNANT WATER
2SAVSOUTH WALL OF THE WEST SIDE OF THE VAULT
2AMHFINISHED WITH WEST SIDE OF VAULT
2SRVROOF OF THE WEST SIDE OF VAULT
2SRVREBAR IS VISIBLE AT THE VERY TOP PORTION OF WEST WALL, ALSO HAS AGGREGATE THROUGHOUT
0AMHWEST SIDE OF VAULT
2SAVNORTH WALL OF THE WEST SIDE OF VAULT

Properties (7)

additional_info
RFIR
custom_field_three
ROOF HAS VISIBLE REBAR THROUGHOUT
custom_field_two
2
customer
LACSD
datetime
2019-02-25T08:51:49-08:00
documentation
OBREGON, YOUNG, BRAR
is_lateral_inspection
false