- Date
- 02/25/2019
- W/O
- 0755897
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00015
- PipeID
- P00143
- Time
- 4:53 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1126
- Sewer Name
- 08 MAIN STREET RELIEF TRUNK
- City
- CARSON
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 07
- Purpose
- Capital Improvement Program Assesment
- Project
- 20190225MDM_MAIN_STREET_RELIEF_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Upstream MH
- 08 0555
- Downstream MH
- 08 0554
- Dir. of Survey
- Downstream
- Length Surveyed
- 473.8 ft.
- Total Length
- 473.8 ft.
- Structural Index
- 2
- Structural Quick
- 2300
- Structural Rating
- 6
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole 08 0555 to 08 0554 Observation photos (5)

2 ft. - General Observation - 70% MAG COAT START

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

101.2 ft. - General Observation - MAG COAT 50% START

101.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE

243.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE