02 0690_02 0689_2212019_023157.mp4
2 ft. - General Observation - MAG COAT 85% START
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SWOLLEN BLISTERING PEELING CONCRETE UNDER MAG COAT
8.7 ft. - Surface Aggregate Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG
35 ft. - Surface Aggregate Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - SEVERE AGG
40.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE
103.1 ft. - Surface Aggregate Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG
125.4 ft. - General Observation - 90% MAG COAT START
351.8 ft. - Surface Aggregate Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG
| Distance | Code | Observation |
|---|---|---|
| 0 | AMH | 2:55AM |
| 103.1 | SAV | SEVERE AGG |
| 2 | MGO | MAG COAT 85% START |
| 40.2 | SSS | BLISTERING PEELING CONCRETE |
| 2 | SSS | SWOLLEN BLISTERING PEELING CONCRETE UNDER MAG COAT |
| 351.8 | SAV | SEVERE AGG |
| 35 | SAV | SEVERE AGG |
| 0 | MWM | — |
| 8.7 | SAV | SEVERE AGG |
| 429.3 | SSS | SWOLLEN BLISTERING PEELING CONCRETE |
| 0 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 429.7 | AMH | 3:35AM |
| 429.3 | MGO | MAG COAT 90% FINISH |
| 0 | MWL | — |
| 125.4 | MGO | 90% MAG COAT START |