Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 19, 2019, 04:29 PM
  • A 0041_A 0040_2192019_120823.mp4

Date
02/19/2019
W/O
0741820
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00334
PipeID
P08416
Time
8:29 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1117
Sewer Name
A JOINT OUTFALL A - UNIT 3C
City
LONG BEACH
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20190219SHO_JOINT_OUTFALL_UNIT_3C
Material
RCP-CTL
Shape
Square
Height
78 in.
Width
78 in.
Upstream MH
A 0041
Downstream MH
A 0040
Dir. of Survey
Downstream
Length Surveyed
1074.2 ft.
Total Length
1074.2 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole A 0041 to A 0040
MH: A 0041MH: A 0040downstream0 ft. MWM - Water Mark, 95 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 00410 ft. MWL - Water Level, 30 %of cross sectional area16.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16.1 ft. MGO - General Observation - 50% MAG COAT INTACT72.5 ft. MGO - General Observation - 30% TILES INTACT128.2 ft. MGO - General Observation - 50% TILES INTACT169.9 ft. MGO - General Observation - 60^ TILES INTACT248.4 ft. MGO - General Observation - 20% TILES INTACT311.6 ft. MGO - General Observation - 15% TILES INTACT374.1 ft. MGO - General Observation - 50% TILES INTACT424.2 ft. MGO - General Observation - 70% TILES INTACT447.5 ft. MGO - General Observation - 100% TILES INTACT447.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish525.1 ft. SAV - Surface Aggregate Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Start568.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start568.1 ft. SAV - Surface Aggregate Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Finish613.7 ft. MGO - General Observation - 50% TILES INTACT973.9 ft. MGO - General Observation - 100% TILES INTACT1005.7 ft. MGO - General Observation - 50% TILES INTACT1074.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1074.2 ft. AMH - Downstream Manhole, Survey Ends - A 0040

Observation photos (13)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    16.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - 30% TILES INTACT

    72.5 ft. - General Observation - 30% TILES INTACT

  • General Observation - 50% TILES INTACT

    128.2 ft. - General Observation - 50% TILES INTACT

  • General Observation - 60^ TILES INTACT

    169.9 ft. - General Observation - 60^ TILES INTACT

  • General Observation - 20% TILES INTACT

    248.4 ft. - General Observation - 20% TILES INTACT

  • General Observation - 15% TILES INTACT

    311.6 ft. - General Observation - 15% TILES INTACT

  • General Observation - 50% TILES INTACT

    374.1 ft. - General Observation - 50% TILES INTACT

  • General Observation - 70% TILES INTACT

    424.2 ft. - General Observation - 70% TILES INTACT

  • General Observation - 100% TILES INTACT

    447.5 ft. - General Observation - 100% TILES INTACT

  • Surface Aggregate Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Start

    525.1 ft. - Surface Aggregate Visible, from 09 to 12 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    568.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - 100% TILES INTACT

    973.9 ft. - General Observation - 100% TILES INTACT

  • General Observation - 50% TILES INTACT

    1005.7 ft. - General Observation - 50% TILES INTACT

Observations (22)

DistanceCodeObservation
525.1SAV
1074.1SAP
374.1MGO50% TILES INTACT
424.2MGO70% TILES INTACT
169.9MGO60^ TILES INTACT
1005.7MGO50% TILES INTACT
0MWM
128.2MGO50% TILES INTACT
311.6MGO15% TILES INTACT
568.1SAP
447.5MGO100% TILES INTACT
0AMHA 0041
1074.2AMHA 0040
72.5MGO30% TILES INTACT
568.1SAV
248.4MGO20% TILES INTACT
16.1SAP
613.7MGO50% TILES INTACT
16.1MGO50% MAG COAT INTACT
0MWL
447.5SAP
973.9MGO100% TILES INTACT

Properties (7)

additional_info
RFIR
custom_field_three
AGGREGATE PROJECTING THROUGHOUT
custom_field_two
3
customer
LACSD
datetime
2019-02-19T08:29:57-08:00
documentation
OBREGON, SHADLER, RUVALCABA, BRAR
is_lateral_inspection
false