Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 2, 2018, 06:03 AM
  • 05 0089A_05 0089 _11012018_220912.mpg

Date
11/01/2018
W/O
735493
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05380
Time
11:03 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6208
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
LAWNDALE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
WO_735493_TV05228_NOV2018
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
05 0089A
Downstream MH
05 0089
Dir. of Survey
Downstream
Length Surveyed
143.3 ft.
Total Length
143.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 05 0089A to 05 0089
MH: 05 0089AMH: 05 0089downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 05 0089A0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area143.3 ft. AMH - Downstream Manhole, Survey Ends - 05 0089143.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observations (6)

DistanceCodeObservation
0MGOCONNECTION AT MH 9 O'CLOCK
143.3AMH05 0089
0AMH05 0089A
143.3MGOCONNECTION AT MH 3 O'CLOCK
0MWL
0MWM

Properties (7)

additional_info
SC365236
custom_field_two
4
customer
LACSD
datetime
2018-11-01T23:03:53-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
FR POLY LINE