Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 1, 2018, 10:30 AM
  • 05 0175_05 0174 _11012018_024049.mp4

Date
11/01/2018
W/O
735493
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05467
Time
3:30 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6207
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
WO_735493_TV05228_NOV2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 0174
Downstream MH
05 0175
Dir. of Survey
Upstream
Length Surveyed
331.3 ft.
Total Length
331.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 05 0174 to 05 0175
MH: 05 0174MH: 05 0175upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 017559 ft. RBL - Roots Ball Lateral, at 02 o'clock, 65 %59 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"62.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"97 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"115.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"186.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"244.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"249.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"300.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"331.3 ft. MWL - Water Level, 15 %of cross sectional area331.3 ft. AMH - Downstream Manhole, Survey Begins - 05 0174331.3 ft. MWM - Water Mark, 20 %of cross sectional area

Observations (13)

DistanceCodeObservation
0MWL
272.3RBL
81.6TF
30.6TF
269.2TF
216.1TF
0AMH05 0174
145.1TF
0MWM
234.3TF
87.1TF
331.3AMH05 0175
272.3TF

Properties (7)

additional_info
SC365235
custom_field_two
4
customer
LACSD
datetime
2018-11-01T03:30:22-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP