Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 22, 2019, 08:51 AM
  • 02 1842_02 1841_01222019_011705.mpg

Date
01/22/2019
W/O
745532
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00283
PipeID
P04187
Time
12:51 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5341
Sewer Name
02 MONTEBELLO INTERCEPTOR TRUNK, SECTS 1&2
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
17
Purpose
Routine Assessment
Project
RIFR_WO_745532_TV02213_JAN2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
02 1842
Downstream MH
02 1841
Dir. of Survey
Downstream
Length Surveyed
644.8 ft.
Total Length
644.8 ft.
Structural Index
5
Structural Quick
5V3A
Structural Rating
611
O&M Index
3
O&M Quick
4111
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
616
Pipe schematic from manhole 02 1842 to 02 1841
MH: 02 1842MH: 02 1841downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 18420 ft. MWL - Water Level, 35 %of cross sectional area8.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start69 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish69 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start481.1 ft. RFJ - Roots Fine Joint, at 09 o'clock, within 8 inches of joint: YES643.1 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish644.8 ft. AMH - Downstream Manhole, Survey Ends - 02 1841

Observation photos (2)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    8.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    69 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
644.8AMH02 1841
69SAP
0MWM
8.9SAP
643.1SRV
481.1RFJ
0AMH02 1842
0MWL
69SRV

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-01-22T00:51:40-08:00
documentation
PROPIPE
is_lateral_inspection
false