Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 27, 2018, 08:52 AM
  • 22 0442_22 0441 _12272018_005826.mp4

Date
12/27/2018
W/O
740124
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00815
PipeID
P16779
Time
12:52 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6305
Sewer Name
22 LARK ELLEN TRUNK, SECTS 2&3
City
COVINA
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_740124_TV22047_DEC2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0442
Downstream MH
22 0441
Dir. of Survey
Downstream
Length Surveyed
114.9 ft.
Total Length
114.9 ft.
Structural Index
3
Structural Quick
3D00
Structural Rating
69
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
69
Pipe schematic from manhole 22 0442 to 22 0441
MH: 22 0442MH: 22 0441downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 04420 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start114.9 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK114.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish114.9 ft. AMH - Downstream Manhole, Survey Ends - 22 0441

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
0AMH22 0442
2.1SAV
114.9MGOCONNECTION AT MH 3 O'CLOCK
0MGOCONNECTION AT MH 3 O'CLOCK
0MWM
114.9SAV
114.9AMH22 0441

Properties (6)

additional_info
SC365489
custom_field_two
3
customer
LACSD
datetime
2018-12-27T00:52:43-08:00
documentation
PROPIPE
is_lateral_inspection
false