- Date
- 02/12/2019
- W/O
- 0754498
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00431
- PipeID
- P05469
- Time
- 12:19 PM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Jetting
- Media Label
- G7915
- Sewer Name
- 05 DISTRICT #5 MAIN TRUNK
- City
- INGLEWOOD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 06
- Purpose
- Maintenance Related
- Project
- 20190212SHO_DISTRICT_5_MAIN_TRUNK
- Material
- NRCP
- Shape
- Circular
- Height
- 14.380000114440918 in.
- Upstream MH
- 05 0177
- Downstream MH
- 05 0176
- Dir. of Survey
- Downstream
- Length Surveyed
- 314.9 ft.
- Total Length
- 314.9 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 3
- O&M Quick
- 3121
- O&M Rating
- 5
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole 05 0177 to 05 0176 Observation photos (4)

41.3 ft. - Roots Medium Lateral, from 12 to 04 o'clock, 35 %, within 8 inches of joint: YES - BEFORE

41.5 ft. - General Photograph - AFTER CLEANING - FINE ROOTS

130.4 ft. - Roots Fine Barrell, from 02 to 04 o'clock, within 8 inches of joint: YES

314.9 ft. - Downstream Manhole, Survey Ends - ZOOMED TO MH 176