Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2019, 12:19 PM
  • 18 0385_18 0384_262019_043031.mp4

Date
02/06/2019
W/O
0753892
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00690
PipeID
P14219
Time
4:19 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1099
Sewer Name
18 NORTH NORWALK TRUNK
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Capital Improvement Program Assesment
Project
20190206MDM_NORTH_NORWALK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
18 0385
Downstream MH
18 0384
Dir. of Survey
Downstream
Length Surveyed
263.9 ft.
Total Length
263.9 ft.
Structural Index
2
Structural Quick
382D
Structural Rating
74
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
74
Pipe schematic from manhole 18 0385 to 18 0384
MH: 18 0385MH: 18 0384downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:30AM4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE8 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT11.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H17.5 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SL17.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL23.9 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H30.2 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SL30.2 ft. FC - Fracture Circumferential, from 09 to 04 o'clock, within 8 inches of joint: YES - H64.3 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL64.3 ft. FC - Fracture Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES - SL98.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL98.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SL107 ft. MGO - General Observation - 12" VCP117 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H120.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL120.2 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SL123.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H129.7 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - SL141.8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H157.1 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H163.7 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL166.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL185.4 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H201 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL207.4 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SL210.2 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL213.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H216.1 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H222.6 ft. FC - Fracture Circumferential, from 08 to 01 o'clock, within 8 inches of joint: YES - SL238.1 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SL238.1 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H250.6 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - H260.3 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL260.3 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H263.6 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active263.9 ft. AMH - Downstream Manhole, Survey Ends - 5:00AM

Observation photos (1)

  • General Observation - 12" VCP

    107 ft. - General Observation - 12" VCP

Observations (40)

DistanceCodeObservation
222.6FCSL
30.2FLSL
117FLH
216.1FCH
8FCSLIGHT
157.1FLH
30.2FCH
98.7FCSL
185.4FLH
0MWM
210.2FCSL
17.5FCSL
0MGOConn. @ Mh, 3 O' Clock. Active
163.7FCSL
64.3FCSL
11.4FCH
0MWL
201FCSL
166.6FCSL
98.7FLSL
238.1FCSL
129.7FCSL
107MGO12" VCP
250.6FCH
207.4FLSL
0AMH4:30AM
4FCHAIRLINE
17.5FCSL
141.8FCH
120.2FCSL
23.9FCH
120.2FLSL
263.9AMH5:00AM
64.3FCSL
238.1FCH
260.3FCSL
213.4FCH
263.6MGOConn. @ Mh, 3 O' Clock. Active
260.3FCH
123.4FLH

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2019-02-06T04:19:10-08:00
documentation
MARTIN,CASTILLO
is_lateral_inspection
false