Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2019, 06:10 PM
  • Section#1_01 1309_01 1308__212019__I0118.mp4

Date
02/01/2019
W/O
PENDING
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00198
PipeID
P01605
Time
10:10 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0118
Sewer Name
01 BULLIS ROAD-TEMPLE STREET RELIEF TRUNK
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Maintenance Related
Project
20190201SHO_BULLIS_ROAD_TEMPLE_STREET_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Upstream MH
01 1309
Downstream MH
01 1308
Dir. of Survey
Downstream
Length Surveyed
150 ft.
Total Length
150 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 01 1309 to 01 1308
MH: 01 1309MH: 01 1308downstream0 ft. AMH - Upstream Manhole, Survey Begins - MH 13090 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 55 %of cross sectional area150 ft. MSA - Survey Abandoned - NO SIGNS OF DAMAGE

Observations (4)

DistanceCodeObservation
0AMHMH 1309
0MWL
0MWM
150MSANO SIGNS OF DAMAGE

Properties (8)

additional_info
LOOKING FOR ANY POSSIBLE DAMAGE TO THE PIPE THAT COULD CAUSE A SINKHOLE
custom_field_three
EMERGENCY CCTV
custom_field_two
5
customer
LACSD
datetime
2019-02-01T10:10:46-08:00
documentation
OBREGON, MIRANDA, SHADLER
is_lateral_inspection
false
year_laid
19841212