Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2019, 10:32 AM
  • Section#3_18 1049_18 1048__212019__I0116.mp4

Date
02/01/2019
W/O
0753099
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00678
PipeID
P14903
Time
2:32 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0116
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 2A
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Capital Improvement Program Assesment
Project
20190201MDM_LA_HABRA_HEIGHTS_TRUNK_SECTION_2
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
18 1049
Downstream MH
18 1048
Dir. of Survey
Downstream
Length Surveyed
342.5 ft.
Total Length
342.5 ft.
Structural Index
3
Structural Quick
4634
Structural Rating
64
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
64
Pipe schematic from manhole 18 1049 to 18 1048
MH: 18 1049MH: 18 1048downstream0 ft. AMH - Upstream Manhole, Survey Begins - 2:35AM0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - STUB MH CONN 9:007.5 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - SLIGHT22.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT25.6 ft. MGO - General Observation - 8" VCP37.6 ft. FC - Fracture Circumferential, from 06 to 07 o'clock, within 8 inches of joint: YES - HAIRLINE37.6 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - H38.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB50.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN52.1 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES - SL89 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN89.6 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H103 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL103 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL112.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN131.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN142.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB144.3 ft. FC - Fracture Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES - SL156.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SL180.1 ft. FM - Fracture Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES - SL183 ft. FC - Fracture Circumferential, from 07 to 08 o'clock, within 8 inches of joint: YES - H183 ft. FC - Fracture Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES - SL186.4 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - SL186.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SL187 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB200.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SL210.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN212.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL238.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN240.5 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN254.1 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL254.3 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SL254.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN265.9 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL281.1 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H287.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN292.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SL328.8 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL328.8 ft. FC - Fracture Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES - SL329.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN338.2 ft. MGO - General Observation - RAT338.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB342.5 ft. AMH - Downstream Manhole, Survey Ends - 3:45AM

Observation photos (4)

  • General Observation - 8" VCP

    25.6 ft. - General Observation - 8" VCP

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES - SL

    52.1 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES - SL

  • Fracture Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES - SL

    180.1 ft. - Fracture Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES - SL

  • General Observation - RAT

    338.2 ft. - General Observation - RAT

Observations (45)

DistanceCodeObservation
0AMH2:35AM
212.3FMSL
103FCSL
186.4FCSL
265.9FCSL
187TFCSTUB
292.7FMSL
50.2TFOPEN
329.5TFOPEN
254.1FCSL
22.6FLSLIGHT
142.4TFCSTUB
37.6FCHAIRLINE
89TFOPEN
0MWL
342.5AMH3:45AM
254.3FLSL
338.2MGORAT
180.1FMSL
287.8TFOPEN
183FCH
7.5FCSLIGHT
0MWM
103FCSL
328.8FCSL
254.9TFOPEN
38.6TFCSTUB
52.1FMSL
89.6FLH
338.2TFCSTUB
186.4FLSL
25.6MGO8" VCP
238.6TBOPEN
210.4TFOPEN
37.6FCH
281.1FCH
131.9TBOPEN
183FCSL
200.7FMSL
0MGOSTUB MH CONN 9:00
144.3FCSL
240.5TFOPEN
328.8FCSL
112.9TFOPEN
156.4FMSL

Properties (6)

custom_field_three
MULIPLE SLIGHT FRACTURES
custom_field_two
2
customer
LACSD
datetime
2019-02-01T02:32:25-08:00
documentation
MARTIN,REVELES,BRAR
is_lateral_inspection
false