Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 26, 2018, 09:30 AM
  • H 1361_H 1360 _11262018_014902.mp4

Date
11/26/2018
W/O
735502
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01187
PipeID
P26158
Time
1:30 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6204
Sewer Name
H JOINT OUTFALL H - UNIT 5D RELIEF
City
EL MONTE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
WO_735502_TV15242_NOV2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Rectangular
Height
36 in.
Width
36 in.
Upstream MH
H 1361
Downstream MH
H 1360
Dir. of Survey
Downstream
Length Surveyed
502.3 ft.
Total Length
502.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2j00
O&M Rating
428
Overall Index
2
Overall Quick
Overall Rating
428
Pipe schematic from manhole H 1361 to H 1360
MH: H 1361MH: H 1360downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 13610 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start432.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS500.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish500.2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish500.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish502.3 ft. AMH - Downstream Manhole, Survey Ends - H 1360

Observation photos (2)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
502.3AMHH 1360
2DAE
0MWL
2DAGS
500.2DSZ
0AMHH 1361
500.2DAE
500.2DAGS
432.2DSZDEBRIS
0MWM

Properties (7)

additional_info
SC365370
custom_field_two
4
customer
LACSD
datetime
2018-11-26T01:30:33-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
40073