Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 30, 2018, 10:45 AM
  • A 0936_A 0935 _11302018_025320.mp4

Date
11/30/2018
W/O
735496
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P18906
Time
2:45 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6239
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_735496_TV21115_NOV2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
A 0936
Downstream MH
A 0935
Dir. of Survey
Downstream
Length Surveyed
86.7 ft.
Total Length
86.7 ft.
Structural Index
2
Structural Quick
2B00
Structural Rating
34
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
34
Pipe schematic from manhole A 0936 to A 0935
MH: A 0936MH: A 0935downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 09360 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area3.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start86.7 ft. AMH - Downstream Manhole, Survey Ends - A 093586.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MWM
86.7AMHA 0935
0AMHA 0936
0MGOCONNECTION AT MH 9 O'CLOCK
3.9SSS
0MWL
86.7SSS

Properties (7)

additional_info
SC365467
custom_field_two
3
customer
LACSD
datetime
2018-11-30T02:45:02-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
34095