Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2019, 09:37 AM
  • Section#2_15 0748_15 0747__1282019__I0106.mp4

Date
01/28/2019
W/O
0749484
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P12948
Time
1:37 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0106
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20190128MDM_ARCADIA_SIERRA_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0748
Downstream MH
15 0747
Dir. of Survey
Downstream
Length Surveyed
345.7 ft.
Total Length
345.7 ft.
Structural Index
3
Structural Quick
4M2M
Structural Rating
414
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
414
Pipe schematic from manhole 15 0748 to 15 0747
MH: 15 0748MH: 15 0747downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - ACTIVE MH CONN 6:000 ft. AMH - Upstream Manhole, Survey Begins - 2:20AM0 ft. MGO - General Observation - ACTIVE MH CONN 9:002 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTCHED2 ft. MGO - General Observation - MAG COAT 10% START11.3 ft. MGO - General Observation - 60% MAG COAT START112.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN161.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN260.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN305.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN329.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN345.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - PEELING ONCRETE SEVERE AGG ATTACHED345.2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG345.2 ft. MGO - General Observation - 60% MAG COAT FINISH345.2 ft. MGO - General Observation - ACTIVE MH CONN 3:00345.7 ft. AMH - Downstream Manhole, Survey Ends - 2:50AM

Observation photos (3)

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTCHED

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTCHED

  • General Observation - MAG COAT 10% START

    2 ft. - General Observation - MAG COAT 10% START

Observations (19)

DistanceCodeObservation
11.3MGO60% MAG COAT START
260.3TFOPEN
2SAMSEVERE AGG
2SSSPEELING CONCRETE SEVERE AGG ATTCHED
161.9TFOPEN
345.7AMH2:50AM
345.2SSSPEELING ONCRETE SEVERE AGG ATTACHED
345.2SAMSEVERE AGG
329.7TFOPEN
0MWL
345.2MGO60% MAG COAT FINISH
0MWM
2MGOMAG COAT 10% START
112.1TFOPEN
0MGOACTIVE MH CONN 6:00
0AMH2:20AM
0MGOACTIVE MH CONN 9:00
345.2MGOACTIVE MH CONN 3:00
305.3TFOPEN

Properties (6)

custom_field_three
PEELING CONCRETE SEVERE AGG ATTACHED
custom_field_two
2
customer
LACSD
datetime
2019-01-28T01:37:59-08:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false