18 0297_18 0558_172019_032908.mp4
2 ft. - Surface Aggregate Missing, from 07 to 09 o'clock, within 8 inches of joint: YES, Start - SEVERE VAGG
2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
2 ft. - Surface Aggregate Missing, from 04 to 05 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
10.2 ft. - Surface Reinforcement Visible, from 04 to 05 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
14.3 ft. - Surface Aggregate Missing, from 07 to 09 o'clock, within 8 inches of joint: NO - SEVERE AGG
18.9 ft. - Surface Aggregate Missing, from 07 to 05 o'clock, within 8 inches of joint: YES - SEVERE AGG
19.2 ft. - Surface Reinforcement Visible, from 07 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR
35.2 ft. - Surface Reinforcement Visible, from 07 to 09 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
42.3 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - PEELED CONCRETE
59.4 ft. - Surface Reinforcement Visible, from 04 to 05 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
68.5 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
137.5 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
143.3 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - PEELED CONCRETE
180.8 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
192.3 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
212.5 ft. - General Observation - MAG COAT 20%
238.5 ft. - Surface Reinforcement Visible, from 04 to 05 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
350.4 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
406 ft. - Surface Reinforcement Visible, from 11 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
| Distance | Code | Observation |
|---|---|---|
| 0 | AMH | 3:40AM |
| 377.3 | TFC | Capped |
| 21.1 | TFC | Capped |
| 280.1 | TFC | Capped |
| 19.2 | SRV | LONG & CIRCUM REBAR |
| 137.5 | SAV | SEVERE AGG |
| 0 | MWM | — |
| 421.3 | MGO | Conn. @ Mh, 9 O' Clock. OPEN |
| 2 | SAM | SEVERE VAGG |
| 137.5 | SAM | SEVERE AGG |
| 29.9 | TFC | Capped |
| 384.9 | TFC | Capped |
| 406 | SRV | CIRCUM REBAR |
| 223.9 | TF | Open |
| 45.2 | SRV | LONG & CIRCUM REBAR |
| 137.5 | SAV | SEVERE AGG |
| 421.8 | AMH | 4:40AM |
| 10.2 | SRV | CIRCUM REBAR |
| 0 | MWL | NO FLOW |
| 2 | SAV | SEVERE AGG SPORATIC |
| 137.5 | SAM | SEVERE AGG |
| 168 | TFC | Capped |
| 143.3 | DSZ | PEELED CONCRETE |
| 421.3 | SSS | PEELING BLISTERING CONCRETE |
| 247.7 | SRV | CIRCUM REBAR |
| 192.3 | SRV | CIRCUM REBAR |
| 180.8 | SSS | PEELING CONCRETE |
| 272.4 | TFC | Capped |
| 42.3 | DSZ | PEELED CONCRETE |
| 18.9 | SAM | SEVERE AGG |
| 238.5 | SRV | CIRCUM REBAR |
| 173.8 | TFC | Capped |
| 85.5 | TFC | Capped |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 59.4 | SRV | CIRCUM REBAR |
| 350.4 | SRV | CIRCUM REBAR |
| 8 | MGO | 24" RCP |
| 212.5 | MGO | MAG COAT 20% |
| 35.2 | SRV | CIRCUM REBAR |
| 421.3 | DSZ | PEELED CONCRETE; OLD MAG COAT |
| 231.8 | TFC | Capped |
| 134.8 | TFC | Capped |
| 421.3 | SAV | SEVERE AGG |
| 2 | SAM | SEVERE AGG |
| 328.5 | TFC | Capped |
| 126.4 | TFC | Capped |
| 336.5 | TFC | Capped |
| 77.9 | TFC | Capped |
| 14.3 | SAM | SEVERE AGG |
| 68.5 | SSS | PEELING CONCRETE |