Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2019, 07:12 PM
  • Section#2_15 0836_15 0835A__1242019__I0103.mp4

Date
01/24/2019
W/O
0749485
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00594
PipeID
P12644
Time
11:12 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0103
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
ARCADIA
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Routine Assessment
Project
20190124SHO_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_3_2A
Material
NRCP
Shape
Circular
Height
9.399999618530273 in.
Upstream MH
15 0836
Downstream MH
15 0835A
Dir. of Survey
Downstream
Length Surveyed
186.8 ft.
Total Length
186.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 15 0836 to 15 0835A
MH: 15 0836MH: 15 0835Adownstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 8360 ft. MWL - Water Level, 20 %of cross sectional area1.9 ft. LFBK - Lining Failure Buckled, from 11 to 01 o'clock, within 8 inches of joint: YES93.9 ft. RFL - Roots Fine Lateral, from 01 to 02 o'clock93.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"186.8 ft. MGO - General Observation - ACTIVE CONNECTION IN THE MH @ 9186.8 ft. AMH - Downstream Manhole, Survey Ends - MH 835A

Observation photos (1)

  • Lining Failure Buckled, from 11 to 01 o'clock, within 8 inches of joint: YES

    1.9 ft. - Lining Failure Buckled, from 11 to 01 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0MWM
93.9RFL
1.9LFBK
0AMHMH 836
93.9TF
186.8MGOACTIVE CONNECTION IN THE MH @ 9
186.8AMHMH 835A
0MWL

Properties (4)

custom_field_three
LINER IS IN GOOD CONDITION
custom_field_two
4
customer
LACSD
datetime