Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 22, 2019, 06:20 PM
  • Section#2_15 0842_15 0841__1222019__I0098.mp4

Date
01/22/2019
W/O
0749485
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00594
PipeID
P12650
Time
10:20 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0098
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
SIERRA MADRE
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Routine Assessment
Project
20190122SHO_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_32A
Material
NRCP
Shape
Circular
Height
9.350000381469727 in.
Upstream MH
15 0842
Downstream MH
15 0841
Dir. of Survey
Downstream
Length Surveyed
367.5 ft.
Total Length
367.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0842 to 15 0841
MH: 15 0842MH: 15 0841downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 84215.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"124 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"367.5 ft. AMH - Downstream Manhole, Survey Ends - MH 841367.5 ft. MGO - General Observation - ACTIVE CONNECTING IN THE MH @ 9

Observations (7)

DistanceCodeObservation
0MWM
367.5AMHMH 841
124TF
0MWL
15.7TF
367.5MGOACTIVE CONNECTING IN THE MH @ 9
0AMHMH 842

Properties (5)

custom_field_three
LINER IS IN GOOD CONDITION
custom_field_two
4
customer
LACSD
datetime
2019-01-22T10:20:12-08:00
lining
CIPP