Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 18, 2019, 05:38 PM
  • Section#2_15 0845_15 0844__1182019__I0096.mp4

Date
01/18/2019
W/O
0749485
Weather
Dry
Operator/Surveyor
IGNACIO
Sewer ID
Z00594
PipeID
P12653
Time
9:38 AM
Certificate
PENDING
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0096
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Routine Assessment
Project
20190118MI_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_3_2A
Material
NRCP
Shape
Circular
Height
9.350000381469727 in.
Upstream MH
15 0845
Downstream MH
15 0844
Dir. of Survey
Downstream
Length Surveyed
177.5 ft.
Total Length
177.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0845 to 15 0844
MH: 15 0845MH: 15 0844downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:17 AM0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area20.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"23.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"125.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"128.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"177.5 ft. AMH - Downstream Manhole, Survey Ends - 10:35 AM177.5 ft. MGO - General Observation - CONNECTION AT MH, 9 OCLOCK, ACTIVE

Observations (9)

DistanceCodeObservation
0AMH10:17 AM
177.5AMH10:35 AM
0MWL
177.5MGOCONNECTION AT MH, 9 OCLOCK, ACTIVE
23.2TFC
125.4TFA
20.2TFA
128.1TFA
0MWM

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2019-01-18T09:38:15-08:00