- Date
- 01/23/2019
- W/O
- 0749484
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00593
- PipeID
- P12959
- Time
- 4:03 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0099
- Sewer Name
- 15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
- City
- ARCADIA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 01
- Purpose
- Capital Improvement Program Assesment
- Project
- 20190118MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 15 0758
- Downstream MH
- 15 0757A
- Dir. of Survey
- Downstream
- Length Surveyed
- 243.7 ft.
- Total Length
- 243.7 ft.
- Structural Index
- 3
- Structural Quick
- 4I2I
- Structural Rating
- 292
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 294
Pipe schematic from manhole 15 0758 to 15 0757A Observation photos (5)

2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

11.7 ft. - General Observation - MAG COAT 15% START

44.9 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED

79.4 ft. - Surface Spalling, from 10 to 01 o'clock, within 8 inches of joint: YES - PEELING CONCRETE SEVERE AGG ATTACHED