Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 22, 2019, 08:45 AM
  • Section#7_15 0819_15 0818__1222019__I0097.mp4

Date
01/22/2019
W/O
0749485
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P13020
Time
12:45 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0097
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Routine Assessment
Project
20190118MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
9.420000076293945 in.
Upstream MH
15 0818
Downstream MH
15 0819
Dir. of Survey
Upstream
Length Surveyed
299.7 ft.
Total Length
299.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3611
O&M Rating
19
Overall Index
3
Overall Quick
Overall Rating
19
Pipe schematic from manhole 15 0818 to 15 0819
MH: 15 0818MH: 15 0819upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:30AM41.2 ft. MGO - General Observation - CIPP LINER46 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE72.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN81.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN100.2 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - OPEN-90% ROOTS100.2 ft. RML - Roots Medium Lateral, from 08 to 10 o'clock, 5 %, within 8 inches of joint: NO148 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN150.9 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - ACTIVE-90% ROOTS203 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 6" - OPEN-20% ROOTS203 ft. RML - Roots Medium Lateral, from 02 to 04 o'clock, 5 %, within 8 inches of joint: NO203 ft. MGO - General Observation - 9.4" NRCP + CIPP252.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN265.3 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - OPEN-70% ROOTS265.3 ft. RFL - Roots Fine Lateral, at 10 o'clock - 3%299.7 ft. MGO - General Observation - MH CONN 9:0 ACTIVE299.7 ft. MWM - Water Mark, 40 %of cross sectional area299.7 ft. AMH - Downstream Manhole, Survey Begins - 12:45AM299.7 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (2)

  • General Observation - 9.4" NRCP + CIPP

    96.7 ft. - General Observation - 9.4" NRCP + CIPP

  • General Observation - CIPP LINER

    258.5 ft. - General Observation - CIPP LINER

Observations (19)

DistanceCodeObservation
148.8TBDACTIVE-90% ROOTS
218.2TBOPEN
0MGOMH CONN 9:0 ACTIVE
34.4TBDOPEN-70% ROOTS
199.5TBDOPEN-90% ROOTS
253.7TBACTIVE
96.7TBDOPEN-20% ROOTS
199.5RML
0MWM
47.3TBOPEN
0AMH12:45AM
96.7RML
96.7MGO9.4" NRCP + CIPP
258.5MGOCIPP LINER
151.7TBOPEN
227.4TBOPEN
299.7AMH1:30AM
0MWL
34.4RFL3%

Properties (6)

additional_info
REVERSE INSPECTION
custom_field_three
CIPP LINER GOOD COND
custom_field_two
4
customer
LACSD
datetime
2019-01-22T00:45:21-08:00
lining
CIPP