Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 18, 2019, 08:40 AM
  • Section#1_15 0829_15 0828__1182019__I0096.mp4

Date
01/18/2019
W/O
0749485
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P13030
Time
12:40 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0096
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Routine Assessment
Project
20190118MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
9.420000076293945 in.
Upstream MH
15 0828
Downstream MH
15 0829
Dir. of Survey
Upstream
Length Surveyed
284.6 ft.
Total Length
284.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0828 to 15 0829
MH: 15 0828MH: 15 0829upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:15AM81.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN165.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN184.5 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN211.6 ft. MGO - General Observation - 9.4" NRCP+ PVCP LINER217.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE223.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN284.6 ft. MWM - Water Mark, 20 %of cross sectional area284.6 ft. MWL - Water Level, 5 %of cross sectional area284.6 ft. AMH - Downstream Manhole, Survey Begins - 12:45AM

Observation photos (1)

  • General Observation - 9.4" NRCP+ PVCP LINER

    73 ft. - General Observation - 9.4" NRCP+ PVCP LINER

Observations (10)

DistanceCodeObservation
202.8TBOPEN
0MWM
118.7TBOPEN
0MWL
284.6AMH1:15AM
61.3TBOPEN
73MGO9.4" NRCP+ PVCP LINER
100.1TBOPEN
0AMH12:45AM
67TBACTIVE

Properties (6)

additional_info
REVERSE INSPECTION
custom_field_three
PVCP LINER GOOD COND
custom_field_two
4
customer
LACSD
datetime
2019-01-18T00:40:38-08:00
lining
PVCP-Folded/Reformed