Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 23, 2019, 05:54 PM
  • 15 0783_15 0781_1232019_101555.mp4

Date
01/23/2019
W/O
0749483
Weather
Damp
Operator/Surveyor
FRANKLIN
Sewer ID
Z00593
PipeID
P12983
Time
9:54 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7902
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
SIERRA MADRE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Routine Assessment
Project
20190118DF_ARCADIA_SIERRA_MADRE_TR_SECTS_2_5
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
15 0783
Downstream MH
15 0781
Dir. of Survey
Downstream
Length Surveyed
266.1 ft.
Total Length
266.1 ft.
Structural Index
2
Structural Quick
2211
Structural Rating
5
O&M Index
1
O&M Quick
2112
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 15 0783 to 15 0781
MH: 15 0783MH: 15 0781downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:13 AM0 ft. MWL - Water Level, 15 %of cross sectional area0.1 ft. MWM - Water Mark, 20 %of cross sectional area3.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.5 ft. CC - Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES46 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - 90% ROOTS/LATERAL46 ft. RFJ - Roots Fine Joint, at 02 o'clock, within 8 inches of joint: YESR - 5%113.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"156.3 ft. MGP - General Photograph181.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open230.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"259.7 ft. RFJ - Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YESR259.7 ft. MGP - General Photograph259.7 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES264 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish266.1 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)266.1 ft. AMH - Downstream Manhole, Survey Ends - 10:29 AM

Observation photos (8)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

    3.5 ft. - Crack Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - 90% ROOTS/LATERAL

    46 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - 90% ROOTS/LATERAL

  • Roots Fine Joint, at 02 o'clock, within 8 inches of joint: YESR - 5%

    46 ft. - Roots Fine Joint, at 02 o'clock, within 8 inches of joint: YESR - 5%

  • General Photograph

    156.3 ft. - General Photograph

  • Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YESR

    259.7 ft. - Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YESR

  • General Photograph

    259.7 ft. - General Photograph

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    259.7 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
181.3TFOpen
259.7RFJ
0AMH10:13 AM
264SSS
3.5SSS
3.5CC
46TFD90% ROOTS/LATERAL
230.2TFA
46RFJ5%
259.7MGP
0MWL
156.3MGP
259.7CL
113.7TFC
266.1MGOGREASE THROUGHOUT THE REACH (5%)
266.1AMH10:29 AM
0.1MWM

Properties (3)

custom_field_two
3
customer
LACSD
datetime