Section#8_A 0510_A 0509__192019__I0087.mp4
0 ft. - General Observation - METAL RUSTED LEAKING PIPE ACROSS MH
2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR UNDER MAG COAT
2 ft. - General Observation - MAG COAT 80% START 8:00 TO 4:00
100.3 ft. - General Observation - 95% MAG COAT START
112 ft. - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT
118 ft. - Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
244.2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT
285.2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR UNDER MAG COAT
| Distance | Code | Observation |
|---|---|---|
| 2 | SAM | SEVERE AGG |
| 0 | MGO | METAL RUSTED LEAKING PIPE ACROSS MH |
| 0 | MWM | — |
| 318.2 | SRV | CIRCUM REBAR |
| 244.2 | SRV | CIRCUM REBAR UNDER MAG COAT |
| 112 | SRV | CIRCUM REBAR UNDER MAG COAT |
| 100.3 | MGO | 95% MAG COAT START |
| 318.2 | SAM | SEVERE AGG |
| 118 | SRV | CIRCUM REBAR |
| 2 | SRV | CIRCUM REBAR UNDER MAG COAT |
| 2 | MGO | MAG COAT 80% START 8:00 TO 4:00 |
| 0 | AMH | 5:15AM |
| 285.2 | SRV | CIRCUM REBAR UNDER MAG COAT |
| 318.7 | AMH | 5:40AM |
| 0 | MWL | — |
| 318.2 | MGO | 95% MAG COAT FINISH |