Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 23, 2018, 07:09 AM
  • 14 0164_14 0163A_08232018_000947.mp4

Date
08/23/2018
W/O
723913
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00584
PipeID
P23489
Time
12:09 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6009
Sewer Name
14 WEST SIDE TRUNK
City
LANCASTER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
17
Purpose
Routine Assessment
Project
WO_723913_TV14035_SEP2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
14 0164
Downstream MH
14 0163A
Dir. of Survey
Downstream
Length Surveyed
110.8 ft.
Total Length
110.8 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
66
O&M Index
2
O&M Quick
2C00
O&M Rating
44
Overall Index
3
Overall Quick
Overall Rating
110
Pipe schematic from manhole 14 0164 to 14 0163A
MH: 14 0164MH: 14 0163Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 14 01640 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start15.5 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"18.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"66.6 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"70.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"110.8 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK110.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish110.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE110.8 ft. AMH - Downstream Manhole, Survey Ends - 14 0163A110.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    110.8 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (14)

DistanceCodeObservation
66.6TFC
2SAP
0AMH14 0164
18.2TFC
70.8TFC
110.8MGOACTIVE CONNECTION AT MH 9 O'CLOCK
110.8DAGS
2DAGS
110.8MGOCOCKROACHES IN MANHOLE
110.8AMH14 0163A
15.5TFC
0MWL
0MWM
110.8SAP

Properties (4)

additional_info
SC364779
custom_field_two
2
customer
LACSD
datetime
2018-08-23T00:09:42-07:00