Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 2, 2019, 08:00 AM
  • 18 0306_18 0305_122019_000814.mp4

Date
01/02/2019
W/O
0744636
Weather
Dry
Operator/Surveyor
Reveles
Sewer ID
Z00683
PipeID
P14137
Time
12:00 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1091
Sewer Name
18 LA MIRADA TRUNK, SECTS 1&2
City
La Mirada
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
31
Purpose
Routine Assessment
Project
12312018VMR_LA_MIRADA_TRUNK_SECTS_1AND_2
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Upstream MH
18 0306
Downstream MH
18 0305
Dir. of Survey
Downstream
Length Surveyed
407.5 ft.
Total Length
407.5 ft.
Structural Index
5
Structural Quick
5C31
Structural Rating
108
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
108
Pipe schematic from manhole 18 0306 to 18 0305
MH: 18 0306MH: 18 0305downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:07 AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2.8 ft. SZC - Surface Other Chemical, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - Scatterred Mag Coat2.8 ft. SRCC - Surface Reinforcement Corroded Chemical, from 10 to 02 o'clock, within 8 inches of joint: NO - Rebar2.8 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO9.2 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - Rebar hanging12.1 ft. SZC - Surface Other Chemical, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - Rebar19.8 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - Rebar21.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - Rebar26.7 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO - Rebar27.6 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Start - Rebar34.4 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Finish - Rebar37.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 2"42.9 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO, Start - Rebar51.5 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO, Finish - Rebar58.8 ft. SRC - Surface Reinforcement Corroded, from 10 to 01 o'clock, within 8 inches of joint: NO, Start - Rebar60.3 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - Hanging Rebar76.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 01 o'clock, within 8 inches of joint: NO, Finish - Rebar86.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 2"115.8 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - Rebar142.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"155.6 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - Rebar164.2 ft. SRC - Surface Reinforcement Corroded, from 12 to 01 o'clock, within 8 inches of joint: NO, Start - Rebar171 ft. SRC - Surface Reinforcement Corroded, from 12 to 01 o'clock, within 8 inches of joint: NO, Finish - Rebar190.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 2", 4"201.2 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Start - Rebar205.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO, Start205.1 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Finish - Rebar209.8 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO, Finish216.3 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO229.6 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO239.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 2"244.9 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO260 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO, Start273.7 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO, Finish287.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 2"325.3 ft. SRC - Surface Reinforcement Corroded, at 11 o'clock, within 8 inches of joint: NO343.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 2" - Open371.7 ft. SRC - Surface Reinforcement Corroded, at 11 o'clock, within 8 inches of joint: NO381.3 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO, Start386.8 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO, Finish392.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 2"407.5 ft. AMH - Downstream Manhole, Survey Ends - 01:15 AM

Observation photos (7)

  • Surface Reinforcement Corroded Chemical, from 10 to 02 o'clock, within 8 inches of joint: NO - Rebar

    2.8 ft. - Surface Reinforcement Corroded Chemical, from 10 to 02 o'clock, within 8 inches of joint: NO - Rebar

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - Rebar hanging

    9.2 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - Rebar hanging

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - Rebar

    19.8 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - Rebar

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Start - Rebar

    27.6 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Start - Rebar

  • Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO, Start - Rebar

    42.9 ft. - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO, Start - Rebar

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - Hanging Rebar

    60.3 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - Hanging Rebar

  • Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - Rebar

    155.6 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - Rebar

Observations (44)

DistanceCodeObservation
343.9TFOpen
27.6SRCRebar
2.8SZCScatterred Mag Coat
209.8SRC
392.4TFC
216.3SRC
26.7SRCRebar
273.7SRC
386.8SRC
9.2SRCRebar hanging
205.1SRC
229.6SRC
51.5SRCRebar
2.8SRCCRebar
325.3SRC
0AMH12:07 AM
201.2SRCRebar
37.7TFC
0MWM
2.8SAV
190.6TFC
34.4SRCRebar
58.8SRCRebar
155.6SRCRebar
60.3SRCHanging Rebar
86.2TFC
0MWL
205.1SRCRebar
287.4TFC
19.8SRCRebar
244.9SRC
142.6TFA
115.8SRVRebar
164.2SRCRebar
42.9SRCRebar
407.5AMH01:15 AM
239.1TFC
12.1SZCRebar
371.7SRC
260SRC
21.1SRCRebar
171SRCRebar
76.1SRCRebar
381.3SRC

Properties (3)

custom_field_two
2
customer
LACSD
datetime
2019-01-02T00:00:00-08:00