- Date
- 12/31/2018
- W/O
- 0744636
- Weather
- Dry
- Operator/Surveyor
- Reveles
- Sewer ID
- Z00683
- PipeID
- P14139
- Time
- 3:46 AM
- Certificate
- U-115-06022630
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1090
- Sewer Name
- 18 LA MIRADA TRUNK, SECTS 1&2
- City
- La Mirada
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 31
- Purpose
- Routine Assessment
- Project
- 12312018VMR_LA_MIRADA_TRUNK_SECTS_1AND_2
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 18 0307
- Downstream MH
- 18 0306A
- Dir. of Survey
- Downstream
- Length Surveyed
- 293.3 ft.
- Total Length
- 293.3 ft.
- Structural Index
- 5
- Structural Quick
- 5A00
- Structural Rating
- 55
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 55
Pipe schematic from manhole 18 0307 to 18 0306A Observation photos (5)

84.2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO

132.3 ft. - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO

182.9 ft. - Surface Other, from 05 to 07 o'clock, within 8 inches of joint: NO - Possible Missing Pipe

187.5 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO, Start

244.4 ft. - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO, Start