Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 30, 2018, 06:25 AM
  • 01 0681_01 0680_20180829_233722.mp4

Date
08/29/2018
W/O
723858
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00199
PipeID
P01390
Time
11:25 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5991
Sewer Name
01 CALIFORNIA AVENUE EXTENSION TRUNK
City
South Gate
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
14
Purpose
Routine Assessment
Project
WO_723858_TV01117_SEP2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
01 0681
Downstream MH
01 0680
Dir. of Survey
Downstream
Length Surveyed
412.9 ft.
Total Length
412.9 ft.
Structural Index
3
Structural Quick
523O
Structural Rating
256
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
256
Pipe schematic from manhole 01 0681 to 01 0680
MH: 01 0681MH: 01 0680downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 06810 ft. MWL - Water Level, 20 %of cross sectional area2.2 ft. MGO - General Observation - MAG COAT2.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start85.3 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO361.9 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO412.9 ft. AMH - Downstream Manhole, Survey Ends - 01 0680412.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO

    85.3 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO

    361.9 ft. - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO

Observations (9)

DistanceCodeObservation
361.9SRV
85.3SRV
412.9AMH01 0680
0MWM
412.9SAP
0AMH01 0681
2.2MGOMAG COAT
2.2SAP
0MWL

Properties (6)

additional_info
SC364805
custom_field_two
2
customer
LACSD
datetime
2018-08-29T23:25:01-07:00
documentation
PRO PIPE
is_lateral_inspection
false