Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 7, 2018, 09:55 AM
  • 05 1354_05 1353 _07112018_015632.mp4

Date
11/07/2018
W/O
735012
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00444
PipeID
P06570
Time
1:55 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6212
Sewer Name
05 GARDENA PUMP TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_735012_TV05295_NOV2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1354
Downstream MH
05 1353
Dir. of Survey
Downstream
Length Surveyed
221.5 ft.
Total Length
221.5 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
132
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
132
Pipe schematic from manhole 05 1354 to 05 1353
MH: 05 1354MH: 05 1353downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 13540 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area3 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start3 ft. MGO - General Observation - MAG COAT19.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"68.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"120.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"171.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"221.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK221.5 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish221.5 ft. AMH - Downstream Manhole, Survey Ends - 05 1353

Observation photos (1)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
221.5MGOCONNECTION AT MH 9 O'CLOCK
68.9TFC
171.4TFC
0AMH05 1354
221.5SAV
0MWL
120.2TFC
0MWM
19.9TFC
3SAV
3MGOMAG COAT
221.5AMH05 1353

Properties (4)

additional_info
SC365240
custom_field_two
3
customer
LACSD
datetime
2018-11-07T01:55:31-08:00