Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 8, 2018, 09:36 AM
  • 05 1336A_05 1336 _08112018_014408.mp4

Date
11/08/2018
W/O
735012
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00444
PipeID
P06553
Time
1:36 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6214
Sewer Name
05 GARDENA PUMP TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_735012_TV05295_NOV2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 1336A
Downstream MH
05 1336
Dir. of Survey
Downstream
Length Surveyed
138.1 ft.
Total Length
138.1 ft.
Structural Index
3
Structural Quick
3D00
Structural Rating
81
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
83
Pipe schematic from manhole 05 1336A to 05 1336
MH: 05 1336AMH: 05 1336downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 1336A0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area2.2 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start2.2 ft. MGO - General Observation - MAG COAT65.4 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start138.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish138.1 ft. AMH - Downstream Manhole, Survey Ends - 05 1336138.1 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Other,  10 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    65.4 ft. - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
2.2SAV
0AMH05 1336A
0MWM
138.1DSZ
65.4DSZ
2.2MGOMAG COAT
138.1AMH05 1336
138.1SAV
0MGOCONNECTION AT MH 3 O'CLOCK
0MWL

Properties (4)

additional_info
SC365242
custom_field_two
3
customer
LACSD
datetime
2018-11-08T01:36:24-08:00