Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 29, 2018, 08:52 AM
  • 03 0412_03 0411 _29112018_005313.mp4

Date
11/29/2018
W/O
735097
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00373
PipeID
P05174
Time
12:52 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6237
Sewer Name
03 MARINA TRUNK, SECTION 4
City
LONG BEACH
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
26
Purpose
Routine Assessment
Project
RFIR_WO_735097_TV03163_NOV2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
03 0412
Downstream MH
03 0411
Dir. of Survey
Downstream
Length Surveyed
298.7 ft.
Total Length
298.7 ft.
Structural Index
4
Structural Quick
4F3A
Structural Rating
167
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
167
Pipe schematic from manhole 03 0412 to 03 0411
MH: 03 0412MH: 03 0411downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03 04120 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH11.1 ft. FS - Fracture Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES26.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start148 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"190.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish231.2 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES245.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start294.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish298.7 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH298.7 ft. AMH - Downstream Manhole, Survey Ends - 03 0411

Observation photos (4)

  • Fracture Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES

    11.1 ft. - Fracture Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    26.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

    231.2 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    245.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
294.2CM
0AMH03 0412
11.1FS
0MWM
245.6CM
231.2FC
298.7MGOCAPPED LATERAL 9 O'CLOCK @ MH
0MWL
190.7FM
298.7AMH03 0411
26.5FM
148TFC
0MGOCAPPED LATERAL 9 O'CLOCK @ MH

Properties (4)

additional_info
SC365465
custom_field_two
2
customer
LACSD
datetime
2018-11-29T00:52:43-08:00