Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 18, 2017, 12:39 AM
  • 01 0396_01 0395_030817_125221.mp4

Date
02/17/2017
W/O
624309
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00208
PipeID
P00875
Time
4:39 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
4315
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Routine Assessment
Project
WO_624309_TV01032_MAR2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0395
Downstream MH
01 0396
Dir. of Survey
Upstream
Length Surveyed
353.9 ft.
Total Length
353.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2M00
O&M Rating
140
Overall Index
2
Overall Quick
Overall Rating
140
Pipe schematic from manhole 01 0395 to 01 0396
MH: 01 0395MH: 01 0396upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 03960 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish0 ft. MGO - General Observation - CONNECTION AT 9 O CLOCK94.6 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"208.1 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"254.1 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"309.9 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4"350.2 ft. MGO - General Observation - PIPE LINED351.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start353.9 ft. MWM - Water Mark, 20 %of cross sectional area353.9 ft. AMH - Downstream Manhole, Survey Begins - 01 0395353.9 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO, Start

    2.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

Observations (12)

DistanceCodeObservation
2.7DAGS
0MWM
145.8TF
44TF
0AMH01 0395
259.3TF
353.9AMH01 0396
353.9DAGS
353.9MGOCONNECTION AT 9 O CLOCK
99.8TF
3.7MGOPIPE LINED
0MWL

Properties (6)

additional_info
SC318730
custom_field_two
4
customer
LACSD
datetime
2017-02-17T16:39:25-08:00
lining
CIPP
year_laid
35628