Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 18, 2017, 12:39 AM
  • 01 0392_01 0391_030817_105429.mp4

Date
02/17/2017
W/O
624309
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00208
PipeID
P00871
Time
4:39 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
4315
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Routine Assessment
Project
WO_624309_TV01032_MAR2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0392
Downstream MH
01 0391
Dir. of Survey
Downstream
Length Surveyed
409.7 ft.
Total Length
409.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2O00
O&M Rating
162
Overall Index
2
Overall Quick
Overall Rating
162
Pipe schematic from manhole 01 0392 to 01 0391
MH: 01 0392MH: 01 0391downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 03924.3 ft. MGO - General Observation - PIPE LINED4.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start17 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"78.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"104.2 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"130 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"155.6 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"181.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"207.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"232.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"258.4 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"283.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"309.4 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"334.6 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"386 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4"409.7 ft. AMH - Downstream Manhole, Survey Ends - 01 0391409.7 ft. MGO - General Observation - CAPPED CONNECTION 3 O CLOCK409.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO, Start

    4.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start

Observations (21)

DistanceCodeObservation
334.6TF
386TF
4.3MGOPIPE LINED
0MWL
0MWM
283.9TF
409.7AMH01 0391
155.6TF
232.5TF
207.3TF
104.2TF
130TF
17TF
181.7TF
409.7MGOCAPPED CONNECTION 3 O CLOCK
309.4TF
258.4TF
78.7TF
409.7DAGS
4.3DAGS
0AMH01 0392

Properties (6)

additional_info
SC318730
custom_field_two
4
customer
LACSD
datetime
2017-02-17T16:39:24-08:00
lining
CIPP
year_laid
35628