Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 20, 2017, 10:19 AM
  • 22 0248_22 0247 _20012017_021946.mpg

Date
01/20/2017
W/O
613646
Weather
Light Rain
Operator/Surveyor
R.VARGAS
Sewer ID
Z00793
PipeID
P16530
Time
2:19 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4085
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
WO_613646_TV22160_JAN2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0248
Downstream MH
22 0247
Dir. of Survey
Downstream
Length Surveyed
291.1 ft.
Total Length
291.1 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
171
O&M Index
2
O&M Quick
2J12
O&M Rating
116
Overall Index
2
Overall Quick
Overall Rating
287
Pipe schematic from manhole 22 0248 to 22 0247
MH: 22 0248MH: 22 0247downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 02480 ft. MWL - Water Level, 20 %of cross sectional area2.2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2.2 ft. MGO - General Observation - MAGNESIUM H.O. START2.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start27.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"49.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"80.1 ft. VC - Vermin Cockroach80.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"102 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"125.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"156.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"180.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"180.6 ft. MGP - General Photograph201.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"219.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"247 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"288.8 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish288.8 ft. MGO - General Observation - MAGNEZIUM H.O. FINISH288.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish291.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE291.1 ft. VC - Vermin Cockroach291.1 ft. AMH - Downstream Manhole, Survey Ends - 22 0247

Observation photos (3)

  • Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2.2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    180.6 ft. - General Photograph

Observations (24)

DistanceCodeObservation
0MWM
2.2DAGS
219.8TFC
291.1MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
27.7TFC
288.8DAGS
288.8MGOMAGNEZIUM H.O. FINISH
291.1VC
156.3TFC
0AMH22 0248
288.8SAV
180.6MGP
125.8TFC
180.5TFC
102TFC
201.3TFC
247TFC
80.1VC
49.8TFC
80.2TFC
0MWL
2.2MGOMAGNESIUM H.O. START
2.2SAV
291.1AMH22 0247

Properties (6)

additional_info
SC318626
custom_field_two
3
customer
LACSD
datetime
2017-01-20T02:19:16-08:00
documentation
PRO PIPE
is_lateral_inspection
false