Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 18, 2015, 10:59 AM
  • H 0360_H 0359_20151118_031421.mp4

Date
11/18/2015
W/O
531052
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00172
PipeID
P10700
Time
2:59 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2865
Sewer Name
H JOINT OUTFALL H - UNIT 2G
City
VERNON, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
16
Purpose
Routine Assessment
Project
WO_531052_TV02281_OCT2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
H 0360
Downstream MH
H 0359
Dir. of Survey
Downstream
Length Surveyed
359.3 ft.
Total Length
359.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412M
O&M Rating
144
Overall Index
2
Overall Quick
Overall Rating
144
Pipe schematic from manhole H 0360 to H 0359
MH: H 0360MH: H 0359downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H0360 (0259)0 ft. MWM - Water Mark, 35 %of cross sectional area7.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start158.3 ft. OBN - Obstacles Construction Debris, 30 %of cross sectional area, from 01 to 05 o'clock - FLOW BAND355.9 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish359.3 ft. AMH - Downstream Manhole, Survey Ends - H 0359 (0313)

Observation photos (1)

  • Obstacles Construction Debris, 30 %of cross sectional area, from 01 to 05 o'clock - FLOW BAND

    158.3 ft. - Obstacles Construction Debris, 30 %of cross sectional area, from 01 to 05 o'clock - FLOW BAND

Observations (7)

DistanceCodeObservation
359.3AMHH 0359 (0313)
158.3OBNFLOW BAND
355.9DAGS
0MWL
0AMHH0360 (0259)
0MWM
7.2DAGS

Properties (5)

additional_info
SC205630
custom_field_two
4
customer
LACSD
datetime
2015-11-18T02:59:00-08:00
is_lateral_inspection
false