16 0553_16 0552 _28092017_023130.mp4
3.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
3.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
36.8 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"
52.6 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"
85.4 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"
89 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"
99.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish
99.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish
| Distance | Code | Observation |
|---|---|---|
| 52.6 | TF | — |
| 2 | SSS | — |
| 85.4 | TFC | — |
| 3.1 | MGO | MAG COAT START |
| 100 | SSS | — |
| 99.8 | MGO | MAG COAT FINISH |
| 99.8 | SAV | — |
| 89 | TBA | — |
| 3.1 | SAV | — |
| 101.7 | MGO | CONNECTION AT MH 9 O'CLOCK ACTIVE |
| 36.8 | TBA | — |
| 3.1 | DAGS | — |
| 0 | MWM | — |
| 101.7 | VC | — |
| 0 | MWL | — |
| 101.8 | AMH | 16 0552 |
| 0 | AMH | 16 0553 |
| 99.7 | DAGS | — |