18 0310A_18 310_12132018_030836.mp4
2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING BLISTERING CONCRETE
2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
3.6 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR
8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
9.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE IN SHEETS
12.5 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
13.4 ft. - Surface Reinforcement Corroded, from 09 to 01 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR
14.8 ft. - Surface Reinforcement Corroded, from 09 to 01 o'clock, within 8 inches of joint: NO - MISSING REBAR
| Distance | Code | Observation |
|---|---|---|
| 9.9 | SSS | PEELING CONCRETE IN SHEETS |
| 0 | MWM | — |
| 8 | SRC | LONG & CIRCUM REBAR |
| 30.8 | AMH | 3:15AM |
| 24.6 | SRC | LONG & CIRCUM REBAR MISSING |
| 2 | SRC | LONG & CIRCUM REBAR |
| 3.6 | SRC | LONG CIRCUM REBAR |
| 12.5 | SAM | SEVERE AGG |
| 0 | AMH | 3:00AM |
| 2 | SSS | PEELING BLISTERING CONCRETE |
| 30.1 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 23.9 | TFC | Capped |
| 13.4 | SRC | LONG CIRCUM REBAR |
| 2 | SAM | SEVERE AGG |
| 14.8 | SRC | MISSING REBAR |
| 30.1 | SSS | PEELING CONCRETYE |
| 8 | SAV | SEVERE AGG SPORATIC |
| 30.1 | SAM | SEVERE AGG |
| 8 | SAM | SEVERE AGG |
| 30.1 | SAV | SEVERE AGG |
| 0 | MWL | — |