Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 11, 2018, 08:56 AM
  • 08 0006_08 0005_12112018_013129.mp4

Date
12/11/2018
W/O
0743258
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00016
PipeID
P00006
Time
12:56 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1069
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20181210MDM_MAIN_STREET_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
08 0006
Downstream MH
08 0005
Dir. of Survey
Downstream
Length Surveyed
264.8 ft.
Total Length
264.8 ft.
Structural Index
5
Structural Quick
5B41
Structural Rating
69
O&M Index
4
O&M Quick
4131
O&M Rating
7
Overall Index
5
Overall Quick
Overall Rating
76
Pipe schematic from manhole 08 0006 to 08 0005
MH: 08 0006MH: 08 0005downstream0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:20AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active1 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 08 to 09 o'clock, , within 8 inches of joint: NO - INSIDE MH2 ft. MGO - General Observation - MISSING TILES 100% START2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SRV - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR3.5 ft. HVV - Hole Void Visible, from 09 to 12 o'clock, within 8 inches of joint: NO - SOIL VISIBLE3.5 ft. HVV - Hole Void Visible, from 09 to 12 o'clock, within 8 inches of joint: NO - SLIGHTLY DEEPER VOID5.6 ft. HVV - Hole Void Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - LARGER AREA OF SOIL5.6 ft. HVV - Hole Void Visible, from 09 to 12 o'clock, within 8 inches of joint: NO - SLIGHTLY DEEPER VOID FINISH5.6 ft. HSV - Hole Soil Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - LARGER AREA OF SOIL7 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR13.1 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR27.7 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR65.5 ft. SRC - Surface Reinforcement Corroded, at 03 o'clock, within 8 inches of joint: NO - MISSING REBAR86.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR114.1 ft. MGO - General Observation - DEEP CORRISON114.1 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN REBAR HANGING125.5 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO - CORRISON BEYOUND REBAR262.3 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG264.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - MISSING BROKEN REBAR264.8 ft. AMH - Downstream Manhole, Survey Ends - 2:10AM

Observation photos (15)

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    2 ft. - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Hole Void Visible, from 09 to 12 o'clock, within 8 inches of joint: NO - SOIL VISIBLE

    3.5 ft. - Hole Void Visible, from 09 to 12 o'clock, within 8 inches of joint: NO - SOIL VISIBLE

  • Hole Void Visible, from 09 to 12 o'clock, within 8 inches of joint: NO - SLIGHTLY DEEPER VOID

    3.5 ft. - Hole Void Visible, from 09 to 12 o'clock, within 8 inches of joint: NO - SLIGHTLY DEEPER VOID

  • Hole Void Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - LARGER AREA OF SOIL

    5.6 ft. - Hole Void Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - LARGER AREA OF SOIL

  • Hole Void Visible, from 09 to 12 o'clock, within 8 inches of joint: NO - SLIGHTLY DEEPER VOID FINISH

    5.6 ft. - Hole Void Visible, from 09 to 12 o'clock, within 8 inches of joint: NO - SLIGHTLY DEEPER VOID FINISH

  • Hole Soil Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - LARGER AREA OF SOIL

    5.6 ft. - Hole Soil Visible, from 12 to 02 o'clock, within 8 inches of joint: NO - LARGER AREA OF SOIL

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

    7 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

    13.1 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    27.7 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

  • Surface Reinforcement Corroded, at 03 o'clock, within 8 inches of joint: NO - MISSING REBAR

    65.5 ft. - Surface Reinforcement Corroded, at 03 o'clock, within 8 inches of joint: NO - MISSING REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

    86.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR

  • General Observation - DEEP CORRISON

    114.1 ft. - General Observation - DEEP CORRISON

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN REBAR HANGING

    114.1 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN REBAR HANGING

  • Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO - CORRISON BEYOUND REBAR

    125.5 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO - CORRISON BEYOUND REBAR

Observations (24)

DistanceCodeObservation
5.6HVVLARGER AREA OF SOIL
2MGOMISSING TILES 100% START
0MWM
86.2SRCLONG & CIRCUM REBAR
262.3SAMSEVERE AGG
125.5SRCCORRISON BEYOUND REBAR
27.7SRCLONG & CIRCUM REBAR
264.8AMH2:10AM
264.2SRCMISSING BROKEN REBAR
3.5HVVSOIL VISIBLE
5.6HVVSLIGHTLY DEEPER VOID FINISH
13.1SRCLONG REBAR
2SAMSEVERE AGG
3.5HVVSLIGHTLY DEEPER VOID
114.1MGODEEP CORRISON
114.1SRCBROKEN REBAR HANGING
1DAGSINSIDE MH
65.5SRCMISSING REBAR
2SRVCIRCUM REBAR
5.6HSVLARGER AREA OF SOIL
7SRCLONG & CIRCUM REBAR
0MWL
0AMH1:20AM
0MGOConn. @ Mh, 3 O' Clock. Active

Properties (4)

custom_field_three
SOIL VISIBLE VOID
custom_field_two
1
customer
LACSD
datetime
2018-12-11T00:56:58-08:00