- Date
- 12/10/2018
- W/O
- 0743924
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00799
- PipeID
- P17277
- Time
- 8:54 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7874
- Sewer Name
- 22 CONEY TRUNK, SECTS 2&3
- City
- AZUSA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 11
- Purpose
- Maintenance Related
- Project
- 20181210DF_CONEY_TRUNK_SECTS_2_3
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 22 0905
- Downstream MH
- 22 0906
- Dir. of Survey
- Upstream
- Length Surveyed
- 286.7 ft.
- Total Length
- 286.7 ft.
- Structural Index
- 3
- Structural Quick
- 5131
- Structural Rating
- 12
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 12
Pipe schematic from manhole 22 0905 to 22 0906 Observation photos (8)

0.1 ft. - Water Mark, 30 %of cross sectional area

0.1 ft. - Water Level, 25 %of cross sectional area

2.3 ft. - Crack Spiral, from 09 to 01 o'clock, within 8 inches of joint: YES

4 ft. - General Photograph

4 ft. - General Photograph

4 ft. - Fracture Spiral, from 09 to 01 o'clock, within 8 inches of joint: YES

4 ft. - Broken, from 09 to 01 o'clock, within 8 inches of joint: YES

14.7 ft. - General Photograph