Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 1, 2016, 08:33 AM
  • 08 0658_08 0657 _12012016_003528.mp4

Date
12/01/2016
W/O
608076
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00446
PipeID
P24621
Time
12:33 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4025
Sewer Name
08 FIGUEROA STREET RELIEF TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_608076_TV08016_DEC2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
08 0657
Downstream MH
08 0658
Dir. of Survey
Upstream
Length Surveyed
300.2 ft.
Total Length
300.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412K
O&M Rating
124
Overall Index
2
Overall Quick
Overall Rating
124
Pipe schematic from manhole 08 0657 to 08 0658
MH: 08 0657MH: 08 0658upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 06580.5 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish298.2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start300.2 ft. MWL - Water Level, 35 %of cross sectional area300.2 ft. MWM - Water Mark, 50 %of cross sectional area300.2 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 8 O'CLOCK300.2 ft. AMH - Downstream Manhole, Survey Begins - 08 0657

Observation photos (1)

  • Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
299.7DAGS
300.2AMH08 0658
0MWL
0MWM
2DAGS
0MGOACTIVE CONNECTION AT MH 8 O'CLOCK
0AMH08 0657

Properties (7)

additional_info
SC306417
custom_field_two
4
customer
LACSD
datetime
2016-12-01T00:33:39-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
37470