Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 12, 2017, 09:33 AM
  • 15 0602_15 0601_12102017_023400.mp4

Date
10/12/2017
W/O
663065
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00601
PipeID
P12534
Time
2:33 AM
Certificate
07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4828
Sewer Name
15 DOUBLE AVENUE TRUNK
City
TEMPLE CITY, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_663065_TV15183_OCT2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0602
Downstream MH
15 0601
Dir. of Survey
Downstream
Length Surveyed
303.6 ft.
Total Length
303.6 ft.
Structural Index
3
Structural Quick
4232
Structural Rating
16
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole 15 0602 to 15 0601
MH: 15 0602MH: 15 0601downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 06020 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area7.5 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"13.5 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"50.6 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES58.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"64.6 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"71.9 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES115.4 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"142.4 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"170.1 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"190.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"205.2 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"215.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES248.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES259.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"292 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"299.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES303.6 ft. AMH - Downstream Manhole, Survey Ends - 15 0601

Observation photos (5)

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    50.6 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    71.9 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    215.8 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    248.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    299.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
64.6TF
248.5FM
0AMH15 0602
50.6CL
142.4TF
58.7TF
303.6AMH15 0601
190.5TF
115.4TF
7.5TFA
170.1TF
0MWM
0MWL
215.8FL
71.9CM
13.5TF
292TF
299.4FM
259.3TF
205.2TF

Properties (6)

additional_info
SC353079
custom_field_two
3
customer
LACSD
datetime
2017-10-12T02:33:11-07:00
documentation
PRO-PIPE
is_lateral_inspection
false