Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 20, 2017, 06:19 AM
  • 32 1166_32 1165_19092017_232507.mp4

Date
09/19/2017
W/O
654216
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00839
PipeID
P19620
Time
11:19 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4881
Sewer Name
32 SAN FERNANDO ROAD TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
WO_630370_TV05315_AUG2017
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 1165
Downstream MH
32 1166
Dir. of Survey
Upstream
Length Surveyed
171.1 ft.
Total Length
171.1 ft.
Structural Index
2
Structural Quick
3B2F
Structural Rating
107
O&M Index
2
O&M Quick
2C00
O&M Rating
36
Overall Index
2
Overall Quick
Overall Rating
143
Pipe schematic from manhole 32 1165 to 32 1166
MH: 32 1165MH: 32 1166upstream0 ft. AMH - Upstream Manhole, Survey Ends - 32 11661.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish3.5 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish91.4 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start103.1 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish103.1 ft. MMC - Material Change, Vitrified clay pipe135.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"168.2 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start169.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start171.1 ft. MWM - Water Mark, 15 %of cross sectional area171.1 ft. AMH - Downstream Manhole, Survey Begins - 32 1165171.1 ft. MWL - Water Level, 15 %of cross sectional area171.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (3)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Material Change, Vitrified clay pipe

    68 ft. - Material Change, Vitrified clay pipe

  • Deposits Settled Other,  10 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    79.7 ft. - Deposits Settled Other, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MWM
0AMH32 1165
2.9SAV
0MWL
2SSS
0MGOCONNECTION AT MH 3 O'CLOCK
35.2TFC
167.6DSZ
171.1AMH32 1166
68SAV
170SSS
79.7DSZ
68MMC

Properties (5)

additional_info
SC345941
custom_field_two
3
customer
LACSD
datetime
2017-09-19T23:19:20-07:00
is_lateral_inspection
false