Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 6, 2016, 10:25 AM
  • 02 1550_02 1549_12062016_023910.mp4

Date
12/06/2016
W/O
607654
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00230
PipeID
P03982
Time
2:25 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3932
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 1
City
EAST LOS ANGELES
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
WO_607654_TV02006_DEC2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 1549
Downstream MH
02 1550
Dir. of Survey
Upstream
Length Surveyed
311.7 ft.
Total Length
311.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 1549 to 02 1550
MH: 02 1549MH: 02 1550upstream0 ft. MGO - General Observation - FLOW DIVERTER IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Ends - 02 15500 ft. MGO - General Observation - LATERAL AT MH 9 O CLOCK1.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish38.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"54.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"75.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"79 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"102.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"126 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"128.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"154.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"174.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"177.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"205.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"226.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"228.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"257.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"280.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"282.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"309.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start311.7 ft. MWL - Water Level, 5 %of cross sectional area311.7 ft. MGO - General Observation - LATERAL AT MH 3 O CLOCK311.7 ft. AMH - Downstream Manhole, Survey Begins - 02 1549311.7 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (25)

DistanceCodeObservation
31.4TFC
105.8TFA
85.1TFC
0MWL
134.4TFC
232.7TFC
0MGOLATERAL AT MH 3 O CLOCK
54.6TFA
209.5TFA
236.3TF
310.5DAGS
0AMH02 1549
2DAGS
311.7MGOFLOW DIVERTER IN MANHOLE
185.7TFC
183.4TFA
137TFA
157.5TFC
311.7AMH02 1550
0MWM
311.7MGOLATERAL AT MH 9 O CLOCK
257.3TFA
83.2TFA
273.1TFA
28.9TFA

Properties (6)

additional_info
SC307676
custom_field_two
4
customer
LACSD
datetime
2016-12-06T02:25:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false