Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 17, 2016, 10:08 AM
  • 29 0136_29 0135 _11172016_020856.mp4

Date
11/17/2016
W/O
596943
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01116
PipeID
P24028
Time
2:08 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4017
Sewer Name
29 SPRING STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
WO_596943_TV29029_NOV2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0135
Downstream MH
29 0136
Dir. of Survey
Upstream
Length Surveyed
276 ft.
Total Length
276 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
135
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
137
Pipe schematic from manhole 29 0135 to 29 0136
MH: 29 0135MH: 29 0136upstream0 ft. ACOM - Cleanout Mainline, Survey Ends - 29 01360 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish3.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"6 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - FRACTURES53.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"56 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"103.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"106.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"154.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"156.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"204.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"207.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"217.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start251.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"253.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES254.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"276 ft. AMH - Downstream Manhole, Survey Begins - 29 0135276 ft. MWL - Water Level, 5 %of cross sectional area276 ft. MGO - General Observation - COCKROACHES IN MANHOLE276 ft. MWM - Water Mark, 5 %of cross sectional area276 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK

Observation photos (4)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    22.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    58.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - FRACTURES

    270 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - FRACTURES

Observations (21)

DistanceCodeObservation
270TFDFRACTURES
272.8TFC
58.3CM
220TFC
22.2CM
21.4TFA
0AMH29 0135
276ACOM29 0136
121.5TFC
172.1TFC
222.7TFC
68.9TFC
71.3TFA
169.7TFC
24.3TFC
0MWL
119.1TFC
0MGOCOCKROACHES IN MANHOLE
276CM
0MWM
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK

Properties (6)

additional_info
SC306409
custom_field_two
3
customer
LACSD
datetime
2016-11-17T02:08:31-08:00
documentation
PRO PIPE
is_lateral_inspection
false