Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 17, 2016, 10:59 AM
  • 05 0402_05 0287 _17102016_040253.mp4

Date
10/17/2016
W/O
592209
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00465
PipeID
P05614
Time
3:59 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3605
Sewer Name
05 IRWIN AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
WO_592209_TV05051_SEP2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 0402
Downstream MH
05 0287
Dir. of Survey
Downstream
Length Surveyed
300 ft.
Total Length
300 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 05 0402 to 05 0287
MH: 05 0402MH: 05 0287downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 04020.1 ft. MWM - Water Mark, 10 %of cross sectional area2.1 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: NO6.1 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES9.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start294.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish300 ft. AMH - Downstream Manhole, Survey Ends - 05 0287300 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK

Observation photos (4)

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: NO

    2.1 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    6.1 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

    294.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observations (9)

DistanceCodeObservation
9.9CM
0MWL
6.1CM
300AMH05 0287
300MGOLATERAL AT MH 9 OCLOCK
0.1MWM
2.1CM
294.1CM
0AMH05 0402

Properties (6)

additional_info
SC306200
custom_field_two
3
customer
LACSD
datetime
2016-10-17T03:59:21-07:00
documentation
PROPIPE
is_lateral_inspection
false