Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 13, 2016, 10:56 AM
  • 02 2263_A 0922 _13102016_035959.mp4

Date
10/13/2016
W/O
592208
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00257
PipeID
P04666
Time
3:56 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3740
Sewer Name
02 DOWNEY-BELLFLOWER RELIEF TRUNK RELOCATION
City
DOWNEY, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
32
Purpose
Routine Assessment
Project
WO_592208_TV02104_SEP2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 2263
Downstream MH
A 0922
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
1
Structural Quick
1100
Structural Rating
1
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 02 2263 to A 0922
MH: 02 2263MH: A 0922downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 22630 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area1 ft. MSC - Shape or Size Change, -, 15", 12"1 ft. MMC - Material Change, Polypropylene1 ft. JOM - Joint Offset Medium2 ft. MSA - Survey Abandoned - DUE TO SIZE CHANGE

Observation photos (3)

  • Shape or Size Change, -, 15", 12"

    1 ft. - Shape or Size Change, -, 15", 12"

  • Material Change, Polypropylene

    1 ft. - Material Change, Polypropylene

  • Joint Offset Medium

    1 ft. - Joint Offset Medium

Observations (7)

DistanceCodeObservation
0AMH02 2263
0MWL
2MSADUE TO SIZE CHANGE
1MSC
1MMC
1JOM
0MWM

Properties (6)

additional_info
SC303727
custom_field_two
5
customer
LACSD
datetime
2016-10-13T03:56:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false