Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 13, 2016, 08:57 AM
  • 02 2266_02 2265 _13102016_020941.mp4

Date
10/13/2016
W/O
592208
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00257
PipeID
P04518
Time
1:57 AM
Certificate
U-507-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3740
Sewer Name
02 DOWNEY-BELLFLOWER RELIEF TRUNK RELOCATION
City
DOWNEY, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
32
Purpose
Routine Assessment
Project
WO_592208_TV02104_SEP2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 2266
Downstream MH
02 2265
Dir. of Survey
Downstream
Length Surveyed
331.6 ft.
Total Length
331.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 2266 to 02 2265
MH: 02 2266MH: 02 2265downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 22660 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK3.7 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: YES191.6 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: NO, 4"289.6 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 4"331.6 ft. AMH - Downstream Manhole, Survey Ends - 02 2265

Observation photos (1)

  • Deposits Attached Grease, 10 %of cross sectional area, from 03 to 04 o'clock,  , within 8 inches of joint: YES

    3.7 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0AMH02 2266
0MWL
3.7DAGS
289.6TBA
0MWM
0MGOCONNECTION AT MH 3 O'CLOCK
191.6TBA
331.6AMH02 2265

Properties (6)

additional_info
SC303727
custom_field_two
4
customer
LACSD
datetime
2016-10-13T01:57:00-07:00
documentation
PRO-PIPE
is_lateral_inspection
false